Link to Index Page

Detail of water tank that buckled

Here is a diagram of the water tank. Buckling occurred at the bottom of the conical portion of the tank, a region of the thin shell subjected to meridional compression combined with circumferential tension. The region where buckling started is shown in the next slide.

Page 7 / 67