Link to Index Page

Vibration of saddle mounted horizontal cylindrical storage tank

From:
Alessandra Fiore, Carlo Rago, Ivo Vanzi, Rita Greco and Bruno Briseghella,

“Seismic behavior of a low-rise horizontal cylindrical tank”, International Journal of Advanced Structural Engineering, Vol. 10, No. 2, pp 143-152, June 2018

ABSTRACT: Cylindrical storage tanks are widely used for various types of liquids, including hazardous contents, thus requiring suitable and careful design for seismic actions. The study herein presented deals with the dynamic analysis of a ground-based horizontal cylindrical tank containing butane and with its safety verification. The analyses are based on a detailed finite element (FE) model; a simplified one-degree-of-freedom idealization is also set up and used for verification of the FE results. Particular attention is paid to sloshing and asynchronous seismic input effects. Sloshing effects are investigated according to the current literature state of the art. An efficient methodology based on an “impulsive-convective” decomposition of the container-fluid motion is adopted for the calculation of the seismic force. The effects of asynchronous ground motion are studied by suitable pseudo-static analyses. Comparison between seismic action effects, obtained with and without consideration of sloshing and asynchronous seismic input, shows a rather important influence of these conditions on the final results.

Page 146 / 216